Trustwave and Cybereason Merge to Form Global MDR Powerhouse for Unparalleled Cybersecurity Value. Learn More

Trustwave and Cybereason Merge to Form Global MDR Powerhouse for Unparalleled Cybersecurity Value. Learn More

Services
Managed Detection & Response

Eliminate active threats with 24/7 threat detection, investigation, and response.

Co-Managed SOC (SIEM)

Maximize your SIEM investment, stop alert fatigue, and enhance your team with hybrid security operations support.

Advisory & Diagnostics

Advance your cybersecurity program and get expert guidance where you need it most.

Penetration Testing

Test your physical locations and IT infrastructure to shore up weaknesses before exploitation.

Database Security

Prevent unauthorized access and exceed compliance requirements.

Email Security

Stop email threats others miss and secure your organization against the #1 ransomware attack vector.

Digital Forensics & Incident Response

Prepare for the inevitable with 24/7 global breach response in-region and available on-site.

Firewall & Technology Management

Mitigate risk of a cyberattack with 24/7 incident and health monitoring and the latest threat intelligence.

Solutions
BY TOPIC
Microsoft Security
Unlock the full power of Microsoft Security
Offensive Security
Solutions to maximize your security ROI
Rapidly Secure New Environments
Security for rapid response situations
Securing the Cloud
Safely navigate and stay protected
Securing the IoT Landscape
Test, monitor and secure network objects
Why Trustwave
About Us
Awards and Accolades
Trustwave SpiderLabs Team
Trustwave Fusion Security Operations Platform
Trustwave Security Colony
Partners
Technology Alliance Partners
Key alliances who align and support our ecosystem of security offerings
Trustwave PartnerOne Program
Join forces with Trustwave to protect against the most advance cybersecurity threats
Loading...
Loading...

INFO: What troubleshooting steps do I take to debug OPSEC LEA connection issues?

Expand / Collapse


This article applies to:

  • Firewall Suite 3.1+

Question:

What troubleshooting steps do I take to debug OPSEC LEA connection issues?

Information:

The OPSEC LEA connection used to retrieve log data from Check Point firewalls may, at times, be difficult to establish. Often, this is a result of a missed step in the Firewall Suite Configuration Guide, or misconfiguration of the firewall rule or the fwopsec.conf file. There are, however, other possible causes.

To access the Firewall Suite Configuration Guide please click the link below:

The following steps will help to determine what issues are occurring with the LEA service:

  1. Edit the webtrends.ini file and under [Defaults] add the following line:

      LeaDebugOn=1

  2. Download DebugView from the following site:

  3. Delete any Firewall Suite profiles that use the OPSEC LEA connection.

  4. Exit and Unload Firewall Suite (close the application, not uninstall).

  5. Restart the machine where Firewall Suite is installed.

  6. Start DebugView and allow it to run in the background.

  7. Start Firewall Suite and create a new profile using OPSEC LEA.

  8. Check the Services window to ensure that the OPSEC LEA service has started. If not, manually try to start the service.

  9. If the OPSEC LEA service fails to start, note the data collected by DebugView for analysis.



The following table will provide some possible causes:

* CP - Check Point

Case
DebugView Message
Pause Before Result
Solution
IP responds - CP not installed COMM_IS_DEAD Immediate Configure Firewall Suite to point to CP Management Server
IP does not respond COMM_IS_DEAD 10-15 seconds Verify IP is correct; verify CP Management Server machine is configured correctly
IP responds - CP installed - fwopsec.conf not configured correctly COMM_IS_DEAD Immediate Configure fwopsec.conf by following instructions in Firewall Suite Configuration Guide
CP installed - ruleset "drops" OPSEC LEA connection from client COMM_IS_DEAD 2-3 minutes Add/edit ruleset to allow OPSEC LEA traffic to and from CP Management Server and the Firewall Suite machine
CP installed - ruleset "rejects" OPSEC LEA connection from client COMM_IS_DEAD Immediate Add/edit ruleset to allow OPSEC LEA traffic to and from CP Management Server and the Firewall Suite machine
WebTrends OPSEC LEA Service times out the connection END_BY_APPLICATION 5 minutes Varies; this message occurs when a connection was initiated, but timed out due to no response from Management Server

Notes:

Do not run DebugView through Windows Terminal Services as no data on the LEA connection will appear.