Initialization error: 1740 - The endpoint is a duplicate


This article applies to:

  • Trustwave MailMarshal (SEG)
  • Trustwave ECM/MailMarshal Exchange

Symptoms:

  • Restarting MailMarshal services
  • Starting MailMarshal services in debug mode
  • Error message: Initialization error. Unable to initialize RPC server
    Make sure you are not already running MailMarshal Engine
    1740 - The endpoint is a duplicate
  • This error can be raised by any MailMarshal service. The service is named in the error text

Causes:

  • The service you are starting or re-starting is already running.
  • MailMarshal services under load can take considerable time to stop, because they must complete existing transactions first.

Resolution:

  • Ensure that the relevant service is stopped and then try again.
  • The preferred action is to wait for the service to stop. You can end the service forcibly, but Trustwave does not recommend doing so as data might be lost.


Last Modified 3/1/2020.